Gas piping and fittings at a heating boiler

NYC Department of Buildings · Gas piping

NYC Local Law 152 Gas Piping Inspections

Periodic gas piping inspections for Queens buildings the law covers. A licensed master plumber inspects and certifies. You confirm the due year from your community district. Call 929-499-2387.

Call 929-499-2387 Request an inspection

Local Law 152 of 2016 requires periodic inspection of gas piping systems in New York City buildings. Flushing Plumbing & Heating Co. does that inspection for covered buildings in Flushing and the rest of Queens. This page is a plain description of the public rule so owners, co-op boards, and managing agents know what to ask. It is not a determination that your building is due.

DOB publishes the rule and the calendar. The pages we are describing are the department's gas piping inspections guide and the rule in 1 RCNY 103-10. If a deadline on this page and the department's page ever disagree, use the department's page. Cycles have been extended by local law before.

Which buildings are covered

DOB says the law applies to buildings except one- and two-family homes and other buildings classified in occupancy group R-3. Other Department of Finance building classes are also outside it. The classification is on the building's property profile in the Buildings Information System. A house in Whitestone or Douglaston is often outside the law. A co-op, a rental walk-up, or a mixed building in Flushing, Forest Hills, Rego Park, or Jamaica often is not. "Often" is not a filing decision. Read the classification.

A new building with gas piping has its first inspection during the tenth year after DOB issues the certificate of occupancy. After that, it joins the community-district cycle.

The four-year cycle follows the community district

Inspections are at least once every four years. The year is the community district of the building, and the same district numbers are used in every borough. Flushing is not one district. Do not pick a year from the neighborhood name. Look the address up with the Department of City Planning, which is what DOB tells owners to do, and then find that district on DOB's chart.

This is the department's published pattern for the cycle that is current as of late 2026. The next inspection for a district is four years after its year:

DOB community-district gas piping cycle, current windows
Community districts, every borough Inspection year
4, 6, 8, 9, and 16 2026, through December 31, 2026
11, 12, 14, 15, and 17 2027
1, 3, and 10 2028
2, 5, 7, 13, and 18 2029

Districts that the rule does not name in the first three groups fall in with districts 11, 12, 14, 15, and 17. Confirm the year on DOB's site before you treat this table as your deadline.

Who may inspect, and what they are looking at

The inspection is done by a licensed master plumber, or by a journeyman plumber under that plumber's direct and continuing supervision who has completed a training program acceptable to DOB. The master plumber certifies it. DOB tells owners to check that the plumber's license is current before they hire.

DOB's current questions and answers say Local Law 142 of 2025 extended the inspection from the point where gas piping enters the building through the connections to the appliances. That includes exposed gas piping and gas appliances in commercial spaces. Piping, equipment, appliances, and connections inside dwelling units are not part of the inspection. Exposed piping in common spaces is, including hallways, roofs, and non-residential tenant spaces. Some commercial classifications are excluded. A storefront and an apartment in the same building are not inspected the same way.

How the filing works now

The paper trail changed in 2026. DOB says that starting July 27, 2026, the old GPS1 and GPS2 forms are no longer required or accepted. Filing is in DOB NOW: Safety. Historical GPS forms that were submitted before that date stay in the building's records. They are not the form for a new cycle.

  • The inspection entity gives the owner an inspection report and a certification no later than 30 days after the inspection. That requirement is in 1 RCNY 103-10.
  • The owner submits the certification to DOB within 60 days of the inspection. The owner attests in DOB NOW and pays the department's filing fee. We do not set that fee, and we do not submit the owner's attestation for them.
  • If the certification says conditions need correction, DOB's instructions call for a follow-up certification that they were corrected, within 120 days of the inspection. If the filing said more time was needed, that window is 180 days.
  • An unsafe or hazardous condition is not one of those windows. The plumber notifies the owner, the gas utility, and DOB immediately, and the owner corrects it under the construction codes, including any permit.

If a property has more than one Building Identification Number, DOB expects each one filed on its own. A lot in Queens with two buildings is a question to settle before the appointment, not after.

A building that is not supplied with gas can still have a filing to make. Do not skip the cycle only because the stoves are electric. Ask, or check the building in DOB NOW, rather than assuming the law does not apply.

What we do on the inspection, and what we do not

  1. You call 929-499-2387 or send the form with the address, the community district if you already know it, and whether you are the owner, the board, or the managing agent.
  2. We confirm we are talking about a covered building. If the classification says the law does not apply, we tell you that instead of selling the visit.
  3. The licensed master plumber, or a qualified journeyman under that plumber's supervision, inspects the exposed gas piping the law covers.
  4. You are told what was found. Anything unsafe is treated as immediate, not as a note for the end of the cycle.
  5. The master plumber certifies the inspection and explains what you have to submit in DOB NOW: Safety, including the 60-day certification and any correction window.

A repair is a separate job from the inspection. If piping has to be opened, that work is estimated on its own, before it starts, and it follows the permit rules described on the gas plumbing and gas line repair page. Passing an inspection is not something we promise. The piping is either in the condition the filing describes, or it is not.

What changes the cost

We do not list a dollar amount. The inspection changes with the amount of exposed piping in the common areas and commercial spaces, the access to meter rooms, roofs, and hallways, the number of Building Identification Numbers on the lot, and whether the visit finds conditions that need a permitted repair. An owner who does not yet have DOB NOW access has a step to do on the city's side. DOB's filing fee is the department's, not ours. A house that is outside the law should not be paying for an inspection the law does not require, and we would rather say that on the phone than on an invoice.

Start with the address

Call 929-499-2387 or send the quote form with the building address. If you already know the community district, include it. For gas work that is not this inspection, go to gas plumbing in Flushing and Queens.

Questions

Does Local Law 152 apply to a one-family or two-family house?

No. DOB states that Local Law 152 of 2016 applies to buildings except one- and two-family homes and other buildings classified in occupancy group R-3. Some other Department of Finance building classes are also outside the law. Check the building's classification on its DOB property profile before you assume you are due.

How often is the inspection, and which year is ours?

Covered buildings are inspected at least once every four years. The year depends on the community district of the building, in every borough, not on the neighborhood name. Look the address up on the Department of City Planning map, then use DOB's chart. Earlier cycles have been extended by local law, so the department's page controls if a deadline moves.

Who is allowed to perform the inspection?

A master plumber licensed by the NYC Department of Buildings, or a journeyman plumber working under that plumber's direct and continuing supervision who has completed a training program DOB accepts. The licensed master plumber certifies the inspection. We do not publish a license number on this site.

Are GPS1 and GPS2 forms still the way to file?

No. DOB says that starting July 27, 2026, GPS1 and GPS2 are no longer required or accepted. Certifications are filed in DOB NOW: Safety. Keep any older GPS1 or GPS2 you already filed. The owner attests in DOB NOW and pays DOB's filing fee. We do not set that fee and we do not log into the owner's account for them.

What gets inspected, and what is left out?

DOB's current guidance says the inspection runs from the point where the gas piping enters the building through the connections to appliances, including exposed piping and appliances in commercial spaces. Piping, equipment, appliances, and connections inside dwelling units are outside that inspection. Exposed piping in common areas, including hallways and roofs, is in it. Some commercial building classes are excluded. Confirm the building against DOB's list.

What happens if the inspection finds something wrong?

DOB distinguishes ordinary conditions that need correction from unsafe or hazardous conditions. Conditions that need correction are filed, and DOB's instructions give a follow-up window of 120 days from the inspection, or 180 days if the filing said more time was needed. An unsafe or hazardous condition is immediate: the plumber notifies the owner, the gas utility, and DOB, and the owner has to correct it, including any permit the repair needs.

Where we inspect

We come to the job. There is no shop address on this site. These are the Flushing-side neighborhoods and ZIP codes, plus every other neighborhood in Queens.

  • Flushing, Murray Hill, and Auburndale 11354, 11355, 11358
  • Whitestone 11357
  • College Point 11356
  • Bayside and Oakland Gardens 11360, 11361, 11364
  • Little Neck and Douglaston 11362, 11363
  • Fresh Meadows 11365, 11366
  • Kew Gardens Hills 11367
  • Kew Gardens 11415
  • Forest Hills 11375
  • Rego Park 11374
  • Jamaica and Briarwood 11432, 11435
  • And all of Queens Every neighborhood

Free on-site estimate

Request a Local Law 152 inspection

Name and phone. We call you back. For a burst pipe, call now.

Need a plumber in Flushing right now?

24/7 emergency service for houses, apartments, and commercial buildings in Queens. Call 929-499-2387 or ask for a free on-site estimate.

Call 929-499-2387
929-499-2387 Get a quote